dc.description.abstractObject A previous study by computational fluid dynamics (CFD) of the three-dimensional (3-D) flow in ventricular catheters (VC) disclosed that most of the total fluid mass flows through the catheter’s most proximal holes in commercially available VC. The aim of the present study is to investigate basic flow patterns in VC prototypes. Methods The general procedure for the development of a CFD model calls for transforming the physical dimensions of the system to be studied into a virtual wire-frame model which provides the coordinates for the virtual space of a CFD mesh, in this case, a VC. The incompressible Navier–Stokes equations, a system of strongly coupled, nonlinear, partial differential conservation equations governing the motion of the flow field, are then solved numerically. New designs of VC, e.g., with novel hole configurations, can then be readily modeled, and the corresponding flow pattern computed in an automated way. Specially modified VCs were used for benchmark experimental testing. Results Three distinct types of flow pattern in prototype models of VC were obtained by varying specific parameters of the catheter design, like the number of holes in the drainage segments and the distance between them. Specifically, we show how to equalize and reverse the flow pattern through the different VC drainage segments by choosing appropriate parameters. Conclusions The flow pattern in prototype catheters is determined by the number of holes, the hole diameter, the ratio hole/segment, and the distance between hole segments. The application of basic design principles of VC may help to develop new catheters with better flow circulation, thus reducing the possibility of becoming occluded.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherSpringeres_ES
dc.rightsinfo:eu-repo/semantics/closedAccesses_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectHydrocephaluses_ES
dc.subjectComputational fluid dynamics (CFD)es_ES
dc.subjectVentricular catheteres_ES
dc.subjectShuntes_ES
dc.subjectCerebrospinal fluid (CSF)es_ES
dc.subjectFlowes_ES
dc.subjectDesignes_ES
dc.titleBasic cerebrospinal fluid flow patterns in ventricular catheters prototypeses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversion10.1007/s00381-015-2651-4es_ES
Aparece en las colecciones:
Artículos- Psicología de la Salud


no-thumbnailVer/Abrir:

 Basic cerebrospinal fluid flow patternsn vetricular cathethers prototypes Childs Nerv Syst 2015.pdf



5,44 MB
Adobe PDF
Compartir:


Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.