Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/35250

Microscopic observation drug susceptibility assay for the diagnosis of TB and MDR-TB in HIV-infected patients: a systematic review and meta-analysis


Vista previa

Ver/Abrir:
 Microscopic observation drug.pdf

404,35 kB
Adobe PDF
Compartir:
Título :
Microscopic observation drug susceptibility assay for the diagnosis of TB and MDR-TB in HIV-infected patients: a systematic review and meta-analysis
Autor :
Wikman-Jorgensen, Philip Erick  
Llenas-García, Jara  
Hobbins, Jochen Ehmer
Abellana, Rosa
Queiroga Gonçalves, Alessandra
Perez-Porcuna, Tomas Maria  
Ascaso, Carlos
Editor :
ERS Publicantios
Departamento:
Departamentos de la UMH::Medicina Clínica
Fecha de publicación:
2014-09-03
URI :
https://hdl.handle.net/11000/35250
Resumen :
The objective of the present study was to assess the diagnostic accuracy of the microscopic observation drug susceptibility (MODS) assay for tuberculosis (TB) diagnosis in HIV-infected patients. MEDLINE, EMBASE, LILACS, the Cochrane Central Register of Controlled Trials, African Index Medicus, ResearchGate, SciELO, and the abstracts of the main conferences on infectious diseases and tropical medicine were searched, and other sources investigated. Only studies including HIV-infected patients evaluating MODS for the diagnosis of TB and using culture-based diagnostic tests as a gold standard were analysed. Summary sensitivity and specificity were calculated with a bivariate model. 3259 citations were found, 29 were selected for full-text review and 10 studies including 3075 samples were finally analysed. Overall diagnostic accuracy of MODS for the diagnosis of TB was a sensitivity of 88.3% (95% CI 86.18-90.2%) and specificity 98.2% (95% CI 97.75-98.55%). For multidrug-resistant (MDR)-TB, sensitivity was 89% (95% CI 66.07-97%) and specificity was 100% (95 CI 94.81-100%). For smear-negative pulmonary TB, a sensitivity of 88.2% (95% CI 86.1-89.9%) and specificity of 98.2% (95% CI 96.8-98.9%) were found. Costs varied between USD 0.72 and 7.31 per sample. Mean time to positivity was 8.24 days. MODS was found to have a good accuracy for the diagnosis of TB and MDR-TB in HIV-infected patients with low cost and fast results.
Tipo de documento :
info:eu-repo/semantics/article
Derechos de acceso:
info:eu-repo/semantics/openAccess
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
DOI :
10.1183/09031936.00079614
Aparece en las colecciones:
Artículos Medicina Clínica



Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.