Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/34732
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorSánchez-Dengra, Bárbara-
dc.contributor.authorGonzález-García, Ignacio-
dc.contributor.authorGonzález Álvarez, Marta-
dc.contributor.authorGonzález Álvarez, Isabel-
dc.contributor.authorBermejo, Marival-
dc.contributor.otherDepartamentos de la UMH::Ingenieríaes_ES
dc.date.accessioned2025-01-16T19:35:05Z-
dc.date.available2025-01-16T19:35:05Z-
dc.date.created2021-01-
dc.identifier.citationEuropean Journal of Pharmaceutics and Biopharmaceutics Volume 158, January 2021, Pages 185-197es_ES
dc.identifier.issn1873-3441-
dc.identifier.issn0939-6411-
dc.identifier.urihttps://hdl.handle.net/11000/34732-
dc.description.abstractFinding predictive dissolution tests and valid IVIVCs are essential activities in generic industry, as they can be used as substitutes of human bioequivalence studies. IVIVCs can be developed by two different strategies: a onestep approach or a two-step approach. The objectives of this work were to compare different deconvolution and convolution methods used in the development of two-step level A IVIVCs and to study if the relationship between the in vitro dissolution rate and the in vivo dissolution rate should guide the decision between using a two-step approach or a one-step approach during the development of a new IVIVC. When the in vitro and the in vivo dissolution rates had a linear relationship, valid and biopredictive two-step IVIVCs were obtained, although there was not a combination of deconvolution and convolution methods that could be named as the best one, as long as all the prediction errors for any combination were within the limits. It was not possible to obtain a valid two-step IVIVC when the relationship between dissolution rates was nonlinear, but the one-step approach was able to overcome this fact and it gave valid IVIVCs regardless of whether the relationship between dissolution rates was linear or non-linear.es_ES
dc.formatapplication/pdfes_ES
dc.format.extent13es_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsinfo:eu-repo/semantics/closedAccesses_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIVIVCes_ES
dc.subjectBioequivalencees_ES
dc.subjectBCSes_ES
dc.subjectPredictive in vivo-dissolutiones_ES
dc.subjectOne-stepes_ES
dc.subjectTwo-stepes_ES
dc.subject.otherCDU::6 - Ciencias aplicadas::62 - Ingeniería. Tecnologíaes_ES
dc.titleTwo-step in vitro-in vivo correlations: Deconvolution and convolution methods, which one gives the best predictability? Comparison with one-step approach.es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://doi.org/10.1016/j.ejpb.2020.11.009es_ES
Aparece en las colecciones:
Artículos Ingeniería


no-thumbnailVer/Abrir:

 1-s2.0-S0939641120303428-main.pdf



4,22 MB
Adobe PDF
Compartir:


Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.