Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/11000/40469Registro completo de metadatos
| Campo DC | Valor | Lengua/Idioma |
|---|---|---|
| dc.contributor.author | Martín Rivera, Fernando | - |
| dc.contributor.author | Rodrigo Mallorca, Darío | - |
| dc.contributor.author | Vidal Vidal, José Vicente Cayetano | - |
| dc.contributor.author | Franco Grau, Luis María | - |
| dc.contributor.author | Sáez Berlanga, Ángel | - |
| dc.contributor.author | Chulvi Medrano, Iván | - |
| dc.contributor.other | Departamentos de la UMH::Ciencias del Deporte | es_ES |
| dc.date.accessioned | 2026-09-07T13:36:49Z | - |
| dc.date.available | 2026-09-07T13:36:49Z | - |
| dc.date.created | 2026 | - |
| dc.identifier.citation | Sensors, 2026, vol.25, nº6 | es_ES |
| dc.identifier.issn | 1424-8220 | - |
| dc.identifier.uri | https://hdl.handle.net/11000/40469 | - |
| dc.description.abstract | Background: Accurate monitoring of eccentric phase velocity is needed to support velocity-based training (VBT), yet field-valid tools for multi-joint exercises are scarce. This study evaluated the concurrent validity and reliability of an optoelectronic device to quantify eccentric phase velocity during the Smith machine back squat. Methods: A total of 20 resistance-trained men completed two sessions and performed three repetitions at three submaximal loads (20, 50, and 70 kg). Eccentric mean velocity and peak velocity (Vmax) were recorded simultaneously using PowerTrackTM and a criterion system (MuscleLabTM). Validity was assessed using ordinary least products regression, Lin’s concordance correlation coefficient (CCC), and Bland–Altam analysis. Reliability was examined via intraclass correlation coefficients (ICC), standard error of measurement (SEM), coefficient of variation, and minimum detectable change. Results: Agreement between devices was very high for Vmax (slope ≈ 1.00; CCC = 0.95), with a small constant bias. Eccentric mean velocity showed proportional bias under higher velocity conditions, whereas overall concordance remained high (CCC = 0.95). Inter-session reliability was excellent (ICC = 0.87–0.96), with low SEM values for eccentric velocity metrics. Conclusions: PowerTrackTM can be a valid and reliable tool for monitoring eccentric phase velocity during the Smith machine back squat, with Vmax representing the most robust metric for applied eccentric VBT. | es_ES |
| dc.format | application/pdf | es_ES |
| dc.format.extent | 14 | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | MDPI | es_ES |
| dc.rights | info:eu-repo/semantics/openAccess | es_ES |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.subject | eccentric phase monitoring | es_ES |
| dc.subject | velocity-based training | es_ES |
| dc.subject | linear position transducer | es_ES |
| dc.subject | back squat | es_ES |
| dc.subject | measurement validity | es_ES |
| dc.subject | reliability | es_ES |
| dc.subject.other | CDU::7 - Bellas artes::79 - Diversiones. Espectáculos. Cine. Teatro. Danza. Juegos.Deportes | es_ES |
| dc.subject.other | CDU::6 - Ciencias aplicadas::62 - Ingeniería. Tecnología::621 - Ingeniería mecánica en general. Tecnología nuclear. Electrotecnia. Maquinaria::621.3 - Ingeniería eléctrica. Electrotecnia. Telecomunicaciones | es_ES |
| dc.subject.other | CDU::6 - Ciencias aplicadas::61 - Medicina::612 - Fisiología | es_ES |
| dc.title | From Physiology to Practice: Validation of Eccentric Velocity Monitoring Using an Optoelectronic System | es_ES |
| dc.type | info:eu-repo/semantics/article | es_ES |
| dc.relation.publisherversion | https://doi.org/10.3390/s26061797 | es_ES |
From_Physiology_to_Practice_Validation_of_Eccentri.pdf
2,62 MB
Adobe PDF
Compartir:
La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.
.png)