Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/11000/37839Registro completo de metadatos
| Campo DC | Valor | Lengua/Idioma |
|---|---|---|
| dc.contributor.author | Aguilar-Valero, Francisco Javier | - |
| dc.contributor.author | Solano, J. P. | - |
| dc.contributor.author | Vicente Quiles, Pedro Ginés | - |
| dc.contributor.other | Departamentos de la UMH::Ingeniería Mecánica y Energía | es_ES |
| dc.date.accessioned | 2025-11-04T10:10:30Z | - |
| dc.date.available | 2025-11-04T10:10:30Z | - |
| dc.date.created | 2014-06 | - |
| dc.identifier.citation | Applied Thermal Engineering, vol. 67 (2014) | es_ES |
| dc.identifier.issn | 1873-5606 | - |
| dc.identifier.issn | 1359-4311 | - |
| dc.identifier.uri | https://hdl.handle.net/11000/37839 | - |
| dc.description.abstract | The method of the equivalent thermal wall has been employed for modeling the transient response of high-inertial thermal bridges. A new strategy is presented in order to adjust the thermal properties of the equivalent three-layered wall, which takes into account the temperature distribution across the thermal bridge in a steady-state heat conduction scenario. Two different thermal bridge topologies created by the junction of a vertical wall and an intermediate or a ground floor slab are analyzed with this method, and its feasibility for the implementation in building energy simulation tools is discussed: if the thermal bridge is not considered, an underestimation of 25% in the heat flux across the bridge is predicted. If the thermal bridge is modeled but its thermal inertia is neglected, a time-delayed heat flux response is retrieved. Conversely, the simulation based on the equivalent wall method provides a response nearly identical to the actual dynamic performance of the thermal bridge. | es_ES |
| dc.format | application/pdf | es_ES |
| dc.language.iso | eng | es_ES |
| dc.rights | info:eu-repo/semantics/closedAccess | es_ES |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.subject | Thermal bridge | es_ES |
| dc.subject | Equivalent thermal wall | es_ES |
| dc.subject | High termal inertia | es_ES |
| dc.subject | Numerical heat conduction | es_ES |
| dc.title | Transient modeling of high-inertial thermal bridges in buildings using the equivalent thermal wall method | es_ES |
| dc.type | info:eu-repo/semantics/article | es_ES |
| dc.relation.publisherversion | http://dx.doi.org/10.1016/j.applthermaleng.2014.03.058 | es_ES |
1_Transient modeling of high-inertial thermal bridges_ATE_2014.pdf
811,83 kB
Adobe PDF
Compartir:
La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.
.png)