Analytical modelling and optimisation of a solar-driven cooling system enhanced with a photovoltaic evaporative chimney


Vista previa

Ver/Abrir:
 2024 ATE 245.pdf

2,63 MB
Adobe PDF
Compartir:
Título :
Analytical modelling and optimisation of a solar-driven cooling system enhanced with a photovoltaic evaporative chimney
Autor :
Ruiz Ramírez, Javier  
Martínez, Pedro Juan
Aguilar-Valero, Francisco Javier  
Lucas Miralles, Manuel  
Editor :
Elsevier
Departamento:
Departamentos de la UMH::Ingeniería Mecánica y Energía
Fecha de publicación:
2024
URI :
https://hdl.handle.net/11000/35397
Resumen :
Solar-driven heat pump systems can significantly reduce the energy use in buildings, thereby contributing to meet Europe’s climate commitments, including building decarbonisation by 2050. The research gap filled by this study is the development of an analytical model of a novel photovoltaic evaporative cooling chimney system previously described in the literature. The models for the system components were validated with experimental data, showing a maximum difference of 5.83%. An optimisation analysis based on the grid energy efficiency ratio as key performance indicator was conducted. The condenser water flow rate was identified as the key variable in this analysis. For a given design environmental and operating conditions, the optimal value for this magnitude was 1.05 m h−1, enabling a 3.8 kW load with only 44.33 W from the grid. The ambient temperature and relative humidity have the greatest influence on the overall system performance. They affect both, the panels’ efficiency and the chiller performance. Their combined influence could lead to a 10.86% reduction in the energy use while meeting the cooling load. The comparative study considering other solar cooling systems, assessed that the use of the solar chimney and the water–water heat pump enhances the overall performance of the main components of the system: 53% improvement for the chiller and 10% for the PV panels. Both effects combined, lead to an average grid energy efficiency ratio of 11.58. This study provides valuable insights for the design and implementation of efficient solar-driven cooling technologies, advancing beyond previous efforts in the literature.
Palabras clave/Materias:
Solar cooling
Solar chimney
Evaporative cooling
HVAC
Área de conocimiento :
CDU: Ciencias aplicadas: Ingeniería. Tecnología: Ingeniería mecánica en general. Tecnología nuclear. Electrotecnia. Maquinaria
Tipo de documento :
info:eu-repo/semantics/article
Derechos de acceso:
info:eu-repo/semantics/openAccess
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
DOI :
https://doi.org/10.1016/j.applthermaleng.2024.122878
Aparece en las colecciones:
Artículos Ingeniería Mecánica y Energía



Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.