Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/33462
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorPardo Pina, Sofía-
dc.contributor.authorferrández-pastor, francisco-javier-
dc.contributor.authorRodriguez, Francisco-
dc.contributor.authorCámara-Zapata, José-María-
dc.contributor.otherDepartamentos de la UMH::Física Aplicadaes_ES
dc.date.accessioned2024-10-11T10:46:25Z-
dc.date.available2024-10-11T10:46:25Z-
dc.date.created2024-05-31-
dc.identifier.citationAgronomy 2024, 14(6), 1187es_ES
dc.identifier.issn2073-4395-
dc.identifier.urihttps://hdl.handle.net/11000/33462-
dc.description.abstractThe increase in ambient temperature decreases crop yields. Therefore, greenhouse cooling techniques can be considered adaptation strategies to climate change. To improve the efficiency of crop production, semi-closed greenhouses are utilized, which reduce the mass and energy transfer from the greenhouse. Frequently, these types of structures include an evaporative panel and a distribution system through perforated inflated ducts. To further improve the management of this type of installation, the present work models its behavior. The proper functioning of these installations greatly depends on temperature, as well as the relative humidity of the exterior air. The results show how the exterior climate conditions affect the values of temperature and relative humidity inside the greenhouse due to its effect on the value of evaporative cooling. The cooling capacity of the air per unit mass of evaporated water is reduced when the temperature and/or humidity of the air to be treated in the evaporative panel increases. Thus, when the exterior air is at 40 °C and its relative humidity is 75%, its temperature after passing through the evaporative panel is 15 °C higher than when the initial state of the exterior air is 30 °C and 30%. The effect of the use of frequency drivers in the fans on energy consumption has also been evaluated. A reduction of 8% in the frequency value causes a 22% decrease in the power consumed and a 15% pressure drop in the circuit. Therefore, reducing the frequency of electrical energy can contribute to energy savings without affecting the climate inside the greenhousees_ES
dc.formatapplication/pdfes_ES
dc.format.extent22es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectEnergy savingses_ES
dc.subjectExtreme weather conditionses_ES
dc.subjectSemi-closed greenhouseses_ES
dc.subjectSustainability of agricultural productiones_ES
dc.titleAnalysis of an Evaporative Cooling Pad Connected to an Air Distribution System of Perforated Polyethylene Tubes in a Greenhousees_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://doi.org/10.3390/agronomy14061187es_ES
Aparece en las colecciones:
Artículos Física Aplicada


Vista previa

Ver/Abrir:
 Analysis of an Evaporative Cooling Pad Connected to.pdf

4,38 MB
Adobe PDF
Compartir:


Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.