Title: Detection of exercise intensity thresholds in patients with chronic heart failure based on correlation properties of heart rate variability |
Authors: Sempere-Ruiz, Noemí Manresa-Rocamora, Agustín Fuertes-Kenneally, Laura Sanz-Rocher, Ana Baladzhaeva, Sabina Climent-Payá, Vicente Moya-Ramón, Manuel Sarabia, José Manuel |
Editor: Springer |
Department: Departamentos de la UMH::Ciencias del Deporte |
Issue Date: 2025-06-25 |
URI: https://hdl.handle.net/11000/40745 |
Abstract:
Purpose This study aimed to assess the agreement between ventilatory thresholds (VT1 and VT2), and heart rate variability
(HRV) thresholds (HRVT1 and HRVT2) based on the alpha 1 index of detrended fluctuation analysis (DFA a1) in patients
with chronic heart failure (CHF). Validating HRV-based thresholds could provide a cost-effective alternative for individualised
exercise intensity prescription, improving safety and efficacy in exercise-based cardiac rehabilitation (CR) programmes.
Methods Twenty CHF patients (13 males, 7 females) performed a cardiopulmonary exercise test (CPET) on a cycle ergometer.
Ventilatory thresholds were identified using a mixed method, while HRV thresholds were determined at DFA a1 values
of 0.75 (HRVT1) and 0.5 (HRVT2). Threshold values for oxygen consumption (
VO2), heart rate (HR), and power output
(PO) were compared with paired t test or Wilcoxon test. Agreement was assessed using correlation coefficients (Pearson’s
r and Spearman’s rho), intraclass correlation coefficient (ICC), and Bland–Altman analysis.
Results HRVT2 showed moderate-to-strong associations with VT2 for VO2
(rho = 0.88, ICC = 0.86), for HR (r = 0.88,
ICC = 0.81) and for PO (r = 0.82, ICC = 0.85). Mean biases were small and limits of agreement (LoA) narrow. HRVT1 correlated
only modestly with VT1 for VO2
(rho = 0.67, ICC = 0.43) and weakly for HR (r = 0.43, ICC = 0.37) and PO (r = 0.49,
ICC = 0.35), with wide LoA.
Conclusion In CHF patients, HRVT2 appears to be a valid, practical surrogate for VT2 and may facilitate personalised
intensity prescription where full CPET is unavailable. HRVT1 showed insufficient agreement with VT1 and should be used
with caution. Larger cohorts and protocol refinements are warranted to confirm these observations and to explore strategies
for improving HRVT1 accuracy.
|
Keywords/Subjects: aerobic exercise cardiac rehabilitation autonomic nervous system DFA a1 ventilatory thresholds cardiopulmonary exercise test |
Knowledge area: CDU: Bellas artes: Diversiones. Espectáculos. Cine. Teatro. Danza. Juegos.Deportes |
Type of document: info:eu-repo/semantics/article |
Access rights: info:eu-repo/semantics/openAccess Attribution-NonCommercial-NoDerivatives 4.0 Internacional |
DOI: https://doi.org/10.1007/s00421-025-05860-9 |
Published in: European Journal of Applied Physiology - Vol. 125 (2025), pp. 3475–3484 |
Appears in Collections: Artículos Ciencias del Deporte
|