Please use this identifier to cite or link to this item:
https://hdl.handle.net/11000/34609
Exploring a Bioequivalence Failure for Silodosin Products Due to Disintegrant Excipients
Title: Exploring a Bioequivalence Failure for Silodosin Products Due to Disintegrant Excipients |
Authors: González Álvarez, Isabel Sánchez-Dengra, Bárbara Rodríguez Gálvez, Raquel Ruiz Picazo, Alejandro González Álvarez, Marta García Arieta, Alfredo Bermejo, Marival |
Editor: MDPI |
Department: Departamentos de la UMH::Ingeniería |
Issue Date: 2022-11-23 |
URI: https://hdl.handle.net/11000/34609 |
Abstract:
Some years ago, excipients were considered inert substances irrelevant in the absorption
process. However, years of study have demonstrated that this belief is not always true. In this
study, the reasons for a bioequivalence failure between two formulations of silodosin are investigated.
Silodosin is a class III drug according to the Biopharmaceutics Classification System, which has
been experimentally proven by means of solubility and permeability experiments. Dissolution tests
have been performed to identify conditions concordant with the non-bioequivalent result obtained
from the human bioequivalence study and it has been observed that paddles at 50 rpm are able to
detect inconsistent differences between formulations at pH 4.5 and pH 6.8 (which baskets at 100 rpm
are not able to do), whereas the GIS detects differences at the acidic pH of the stomach. It has also
been observed that the differences in excipients between products did not affect the disintegration
process, but disintegrants did alter the permeability of silodosin through the gastrointestinal barrier.
Crospovidone and povidone, both derivatives of PVP, are used as disintegrants in the test product,
instead of the pregelatinized corn starch used in the reference product. Permeability experiments
show that PVP increases the absorption of silodosin—an increase that would explain the greater Cmax
observed for the test product in the bioequivalence study.
|
Keywords/Subjects: Biopharmaceutics Classification System (BCS) pharmacokinetics (PK) in vitro dissolution permeability bioequivalence |
Knowledge area: CDU: Ciencias aplicadas: Ingeniería. Tecnología |
Type of document: info:eu-repo/semantics/article |
Access rights: info:eu-repo/semantics/openAccess Attribution-NonCommercial-NoDerivatives 4.0 Internacional |
DOI: https://doi.org/10.3390/pharmaceutics14122565 |
Appears in Collections: Artículos Ingeniería
|