Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/40724
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorSempere-Ruiz, Noemí-
dc.contributor.authorSarabia, José Manuel-
dc.contributor.authorBaladzhaeva, Sabina-
dc.contributor.authorMoya-Ramón, Manuel-
dc.contributor.otherDepartamentos de la UMH::Ciencias del Deportees_ES
dc.date.accessioned2026-09-21T17:18:31Z-
dc.date.available2026-09-21T17:18:31Z-
dc.date.created2024-02-05-
dc.identifier.citationFrontiers in Physiology - Vol. 15 (2024)es_ES
dc.identifier.issn1664-042X-
dc.identifier.urihttps://hdl.handle.net/11000/40724-
dc.description.abstractExercise intensity distribution is crucial for exercise individualization, prescription, and monitoring. As traditional methods to determine intensity thresholds present limitations, heart rate variability (HRV) using DFA a1 has been proposed as a biomarker for exercise intensity distribution. This index has been associated with ventilatory and lactate thresholds in previous literature. This study aims to assess DFA a1’s reliability and validity in determining intensity thresholds during an incremental cycling test in untrained healthy adults. Sixteen volunteers (13 males and 3 females) performed two identical incremental cycling stage tests at least 1 week apart. First and second ventilatory thresholds, lactate thresholds, and HRV thresholds (DFA a1 values of 0.75 and 0.5 for HRVT1 and HRVT2, respectively) were determined in heart rate (HR), relative oxygen uptake (VO2rel), and power output (PO) values for both tests. We used intraclass correlation coefficient (ICC), change in mean, and typical error for the reliability analysis, and paired t-tests, correlation coefficients, ICC, and Bland- Altman analysis to assess the agreement between methods. Regarding reliability, HRV thresholds showed the best ICCs when measured in PO (HRVT1: ICC = .87; HRVT2: ICC = .97), comparable to ventilatory and lactate methods. HRVT1 showed the strongest agreement with LA 2.5 in PO (p = 0.09, r = .93, ICC = .93, bias = 9.9 ± 21.1), while HRVT2 reported it with VT2 in PO (p = 0.367, r = .92, ICC = .92, bias = 5.3 ± 21.9). DFA a1 method using 0.75 and 0.5 values is reliable and valid to determine HRV thresholds in this population, especially in PO values.es_ES
dc.formatapplication/pdfes_ES
dc.format.extent15es_ES
dc.language.isoenges_ES
dc.publisherFrontiers Mediaes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectintensity domainses_ES
dc.subjectgraded exercise testes_ES
dc.subjectDFA alpha 1es_ES
dc.subjectcycle ergometeres_ES
dc.subjectpower outputes_ES
dc.subjectoxygen uptakees_ES
dc.subjectventilatory thresholdses_ES
dc.subjectlactate thresholdses_ES
dc.subject.otherCDU::7 - Bellas artes::79 - Diversiones. Espectáculos. Cine. Teatro. Danza. Juegos.Deporteses_ES
dc.titleReliability and validity of a non-linear index of heart rate variability to determine intensity thresholdses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttp://doi.org/10.3389/fphys.2024.1329360es_ES
Aparece en las colecciones:
Artículos Ciencias del Deporte


Vista previa

Ver/Abrir:
 2024 Sempere - Reliability and validity of DFA for thresholds.pdf

2 MB
Adobe PDF
Compartir:


Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.