Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/40470

Evaluating a New Optical Device for Velocity-Based Training: Validity and Reliability of the PowerTrackTM Sensor


thumbnail_pdf
Ver/Abrir:
 metrology-05-00049-v2-2.pdf

2,84 MB
Adobe PDF
Compartir:
Título :
Evaluating a New Optical Device for Velocity-Based Training: Validity and Reliability of the PowerTrackTM Sensor
Autor :
Martín Rivera, Fernando
Rodrigo Mallorca, Darío
Franco Grau, Luis María
Vidal Vidal, Jose Vicente Cayetano
Sáez Berlanga, Ángel
Chulvi Medrano, Iván
Editor :
MDPI
Departamento:
Departamentos de la UMH::Ciencias del Deporte
Fecha de publicación:
2025
URI :
https://hdl.handle.net/11000/40470
Resumen :
Abstract Background: Velocity-based training (VBT) requires precise measurement devices to monitor neuromuscular performance. PowerTrackTM is a novel optoelectronic device designed to assess movement velocity in resistance training. This study aimed to evaluate the validity and reliability of PowerTrackTM during the Smith machine back squat. Methods: Twenty experienced-trained men performed three repetitions at three submaximal loads (20, 50, and 70 kg) across two sessions. Velocity metrics—mean velocity (MV), mean propulsive velocity (MPV), and maximum velocity (Vmax)—were simultaneously recorded by PowerTrackTM and the criterion device (MuscleLabTM). Validity was assessed via ordinary least products (OLP) regression, Lin’s concordance correlation coefficient (CCC), and Bland–Altman plots. Reliability was determined using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), coefficient of variation (CV), and minimum detectable change (MDC). Results: PowerTrack showed high agreement with MuscleLabTM for MPV and Vmax (slope ≈ 1.00; CCC = 0.95–0.97), while MV presented a proportional bias (slope = 0.83). ICCs ranged from 0.78 to 0.91 across loads, and SEM remained <0.09 m/s for all metrics, indicating excellent relative reliability and acceptable absolute precision. Conclusion: Despite a slight underestimation of MV at light loads, PowerTrackTM proved to be a valid and reliable device for velocity monitoring in VBT contexts.
Palabras clave/Materias:
velocity monitoring
force–velocity profiling
optoelectronic technology
encoder
concurrent validity
reliability
Área de conocimiento :
CDU: Bellas artes: Diversiones. Espectáculos. Cine. Teatro. Danza. Juegos.Deportes
CDU: Ciencias aplicadas: Ingeniería. Tecnología: Ingeniería mecánica en general. Tecnología nuclear. Electrotecnia. Maquinaria: Ingeniería eléctrica. Electrotecnia. Telecomunicaciones
CDU: Ciencias aplicadas: Medicina: Fisiología
Tipo de documento :
info:eu-repo/semantics/article
Derechos de acceso:
info:eu-repo/semantics/openAccess
DOI :
https://doi.org/10.3390/metrology5030049
Publicado en:
Metrology 5.3 (2025): 49
Aparece en las colecciones:
Artículos Ciencias del Deporte



Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.