Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/39637

Time-Frequency Analysis of Motor Imagery During Plantar and Dorsal Flexion Movements Using a Low-Cost Ankle Exoskeleton


Vista previa

Ver/Abrir:
 sensors-25-02987.pdf

10,91 MB
Adobe PDF
Compartir:
Título :
Time-Frequency Analysis of Motor Imagery During Plantar and Dorsal Flexion Movements Using a Low-Cost Ankle Exoskeleton
Autor :
Polo Hortigüela, Cristina
Ortiz, Mario
Soriano Segura, Paula
Iáñez, Eduardo
Azorín, José M.
Editor :
MDPI
Departamento:
Departamentos de la UMH::Ingeniería Mecánica y Energía
Fecha de publicación:
2025
URI :
https://hdl.handle.net/11000/39637
Resumen :
Sensor technology plays a fundamental role in neuro-motor rehabilitation by enabling precise movement analysis and control. This study explores the integration of brain–machine interfaces (BMIs) and wearable sensors to enhance motor recovery in individuals with neuro-motor impairments. Specifically, different time-frequency transforms are evaluated to analyze the correlation between electroencephalographic (EEG) activity and ankle position, measured by using inertial measurement units (IMUs). A low-cost ankle exoskeleton was designed to conduct the experimental trials. Six subjects performed plantar and dorsal flexion movements while the EEG and IMU signals were recorded. The correlation between brain activity and foot kinematics was analyzed using the Short-Time Fourier Transform (STFT), Stockwell (ST), Hilbert–Huang (HHT), and Chirplet (CT) methods. The 8–20 Hz frequency band exhibited the highest correlation values. For motor imagery classification, the STFT achieved the highest accuracy (92.9%) using an EEGNet-based classifier and a state-machine approach. This study presents a dual approach: the analysis of EEG-movement correlation in different cognitive states, and the systematic comparison of four time-frequency transforms for both correlation and classification performance. The results support the potential of combining EEG and IMU data for BMI applications and highlight the importance of cognitive state in motion analysis for accessible neurorehabilitation technologies.
Palabras clave/Materias:
electroencephalography (EEG)
brain–machine interface (BMI)
time-frequency transforms
motor imagery
low-cost exoskeleton
neurorehabilitation
inertial measurement units (IMUs)
Área de conocimiento :
CDU: Ciencias aplicadas: Ingeniería. Tecnología
CDU: Ciencias aplicadas: Medicina: Fisiología
CDU: Generalidades.: Ciencia y tecnología de los ordenadores. Informática.
Tipo de documento :
info:eu-repo/semantics/article
Derechos de acceso:
info:eu-repo/semantics/openAccess
DOI :
https://doi.org/10.3390/s25102987
Publicado en:
Sensors - Vol. 25, Nº 10 (2025)
Aparece en las colecciones:
Artículos Ingeniería Mecánica y Energía