Please use this identifier to cite or link to this item: https://hdl.handle.net/11000/37957
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGomez-Garcia, JM-
dc.contributor.authorGómez-Romero, Francisco Javier-
dc.contributor.authorArencibia Jiménez, Mercedes-
dc.contributor.authorNAVARRO-GRACIA, J.F.-
dc.contributor.authorSánchez-Molla, Manuel-
dc.contributor.otherDepartamentos de la UMH::Medicina Clínicaes_ES
dc.date.accessioned2025-11-07T10:29:25Z-
dc.date.available2025-11-07T10:29:25Z-
dc.date.created2018-04-
dc.identifier.citationInternational Journal for Quality in Health Care, 30(7), 565-570 - April 2018es_ES
dc.identifier.issn1464-3677-
dc.identifier.issn1353-4505-
dc.identifier.urihttps://hdl.handle.net/11000/37957-
dc.description.abstractObjective: To evaluate the appropriateness of magnetic resonance imaging (MRI) of the knee requested by primary care physicians. Design: Retrospective observational study. Setting: Six primary care centres in the Elche Department of Health of the Valencian Community, Spain. Participants: Three hundred patients with knee pain who were prescribed MRI. Main Outcome Measures: Data were collected from the electronic clinical history, which allowed us to assess the appropriateness and inappropriateness of the MRI requests for the knee based on the American College of Radiology (ACR) criteria. A multivariate logistic regression model was used to identify factors associated with an inappropriate request. Results: About 45% (41–49%) of knee MRI prescriptions were assessed as inappropriate. The frequency was higher in female patients (odds ratio, OR = 1.96; P = 0.03). A history of knee trauma and urgent use of MRI were associated with a lower frequency of inappropriate requests (OR = 0.14, P < 0.001 and OR = 0.32, P = 0.03, respectively). In 82% of cases, the request for MRI was deemed inappropriate because it was used as the initial imaging test. The availability of a previous radiograph of the knee significantly reduced the rate of inappropriate requests (OR = 0.05, P < 0.001); only 47% of the patients had a previous radiograph. Conclusions: The percentage of inappropriate knee MRI prescriptions is high. Protocols should be put in place to improve the appropriateness of MRI requests by promoting understanding of the appropriate use of MRI among primary care physicians.es_ES
dc.formatapplication/pdfes_ES
dc.format.extent6es_ES
dc.language.isoenges_ES
dc.publisherOxford University Presses_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectappropriatenesses_ES
dc.subjectknee jointmagnetic resonance imaginges_ES
dc.subjectprimary healthcarees_ES
dc.subjectSpaines_ES
dc.subject.otherCDU::6 - Ciencias aplicadas::61 - Medicinaes_ES
dc.titleAppropriateness of magnetic resonance imaging requested by primary care physicians for patients with knee paines_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://doi.org/10.1093/intqhc/mzy067es_ES
Appears in Collections:
Artículos Medicina Clínica


Thumbnail

View/Open:
 Appropriateness of magnetic resonance imaging requested by primary care physicians for patients with knee pain.pdf

232,72 kB
Adobe PDF
Share:


Creative Commons ???jsp.display-item.text9???