Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/37902

Nasopharyngeal Panbio COVID-19 Antigen Performed at Point-of-Care Has a High Sensitivity in Symptomatic and Asymptomatic Patients With Higher Risk for Transmission and Older Age

Título :
Nasopharyngeal Panbio COVID-19 Antigen Performed at Point-of-Care Has a High Sensitivity in Symptomatic and Asymptomatic Patients With Higher Risk for Transmission and Older Age
Autor :
Masiá, Mar
Fernández-González, Marta  
Sánchez-Molla, Manuel  
Carvajal, Mar
García, José Alberto
Gonzalo Jiménez, Nieves  
Ortiz de la Tabla, Victoria  
Agulló, Vanesa  
Candela, Inmaculada  
Guijarro, Jorge
Gutiérrez, José Antonio
de Gregorio, Carlos
Gutiérrez, Félix  
Editor :
Oxford University Press
Departamento:
Departamentos de la UMH::Medicina Clínica
Fecha de publicación:
2021-02
URI :
https://hdl.handle.net/11000/37902
Resumen :
Background. Performance of point-of-care tests in different clinical scenarios and on different samples remains undetermined. We comprehensively evaluated the performance of the nasopharyngeal Panbio COVID-19 Ag Rapid Test Device. Methods. This is a prospective study that includes consecutive patients attending 3 primary care centers (PCCs) and an emergency department. The antigen test was performed at point-of-care in nasopharyngeal and nasal swabs and in saliva. Positive percent agreement (PPA) and negative percent agreement (NPA) were calculated with the reverse-transcription polymerase chain reaction (RT-PCR) assay as reference standard. Results. Of 913 patients included, 296 (32.3%) were asymptomatic and 690 (75.6%) came from the PCC. Nasopharyngeal swabs were collected from 913 patients, nasal swabs were collected from 659 patients, and saliva was collected from 611 patients. The RT-PCR was positive in 196 (21.5%) nasopharyngeal samples (NPS). Overall, PPA (95% CI) in NPS was 60.5% (53.3–67.4), and it was lower in nasal swabs (44.7%) and saliva (23.1%). Test performance in NPS was largely dependent on the cycle threshold (Ct) in RT-PCR, with PPA of 94% for Ct ≤25 and 80% for Ct <30. In symptomatic patients, the PPA was 95% for Ct ≤25, 85% for Ct <30, and 89% for the symptom triad of fever, cough, and malaise. Performance was also dependent on age, with a PPA of 100% in symptomatic patients >50 years with Ct <25. In asymptomatic patients, the PPA was 86% for Ct <25. In all cases, NPA was 100%. Conclusions. The nasopharyngeal Panbio COVID-19 Ag test performed at point-of-care has a good sensitivity in symptomatic patients with Ct <30 and older age. The test was useful to identify asymptomatic patients with lower Ct values.
Palabras clave/Materias:
antigen
COVID-19
Panbio
point-of-care
SARS-CoV-2
Área de conocimiento :
CDU: Ciencias aplicadas: Medicina
Tipo de documento :
info:eu-repo/semantics/article
Derechos de acceso:
info:eu-repo/semantics/openAccess
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
DOI :
https://doi.org/10.1093/ofid/ofab059
Publicado en:
Open Forum Infectious Diseases, 8(3), ofab059 - February 2021
Aparece en las colecciones:
Artículos Medicina Clínica



Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.