Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/35899
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorSalazar, Julio-
dc.contributor.authorMoreno, Bryan-
dc.contributor.authorMARTÍNEZ-MADRID, MARIA CONCEPCIÓN-
dc.contributor.authorValero Roche, Manuel-
dc.contributor.authorRodrigo-Garcia, Joaquin-
dc.contributor.authorHosseinian, Farah-
dc.contributor.authorMartín-Bermudo, Francisco-
dc.contributor.authorAguado, Manuel-
dc.contributor.authorDe la Torre, Rosa-
dc.contributor.authorMartí, Nuria-
dc.contributor.authorSaura, Domingo-
dc.contributor.otherDepartamentos de la UMH::Agroquímica y Medio Ambientees_ES
dc.date.accessioned2025-03-10T16:53:16Z-
dc.date.available2025-03-10T16:53:16Z-
dc.date.created2023-04-18-
dc.identifier.citationMolecules 2023, 28(8), 3552es_ES
dc.identifier.issn1420-3049-
dc.identifier.urihttps://hdl.handle.net/11000/35899-
dc.description.abstractGas chromatography (GC) techniques for analyzing and determining the cannabinoid profile in cannabis (Cannabis sativa L.) are widely used in standard laboratories; however, these methods may mislabel the profile when used under rapid conditions. Our study aimed to highlight this problem and optimize GC column conditions and mass spectrometry (MS) parameters to accurately identify cannabinoids in both standards and forensic samples. The method was validated for linearity, selectivity, and precision. It was observed that when tetrahydrocannabinol (Δ9-THC) and cannabidiolic acid (CBD-A) were examined using rapid GC conditions, the resulting derivatives generated identical retention times. Wider chromatographic conditions were applied. The linear range for each compound ranged from 0.02 μg/mL to 37.50 μg/mL. The R2 values ranged from 0.996 to 0.999. The LOQ values ranged from 0.33 μg/mL to 5.83 μg/mL, and the LOD values ranged from 0.11 μg/mL to 1.92 μg/mL. The precision values ranged from 0.20% to 8.10% RSD. In addition, forensic samples were analyzed using liquid chromatography (HPLC-DAD) in an interlaboratory comparison test, with higher CBD and THC content than GC–MS determination (p < 0.05) in samples. Overall, this study highlights the importance of optimizing GC techniques to avoid mislabeling cannabinoids in cannabis sampleses_ES
dc.formatapplication/pdfes_ES
dc.format.extent13es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectCannabinoidses_ES
dc.subjectValidationes_ES
dc.subjectGas chromatography (GC)es_ES
dc.subjectHPLCes_ES
dc.subjectOverlappinges_ES
dc.titlePreventing Mislabeling: A Comparative Chromatographic Analysis for Classifying Medical and Industrial Cannabises_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://doi.org/10.3390/molecules28083552es_ES
Aparece en las colecciones:
Artículos Agroquímica y Medio Ambiente


Vista previa

Ver/Abrir:
 Preventing Mislabeling a Comparative Chromatographic Analysis.pdf

1,08 MB
Adobe PDF
Compartir:


Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.