Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/33540
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.advisorPoveda Pagán, Emilio José-
dc.contributor.advisorSanabria Alcaraz, Manuel-
dc.contributor.authorChaer Rian, Rania-
dc.contributor.otherDepartamentos de la UMH::Patología y Cirugíaes_ES
dc.date.accessioned2024-10-16T12:37:54Z-
dc.date.available2024-10-16T12:37:54Z-
dc.date.created2024-05-31-
dc.identifier.urihttps://hdl.handle.net/11000/33540-
dc.description.abstractINTRODUCCIÓN: El dolor cervical constituye un problema de salud global, con una prevalencia del 20% y una persistencia en hasta el 50% después de un año. La debilidad de los flexores cervicales profundos se identifica como un factor relevante en la etiología de este dolor, haciendo imprescindible su evaluación. OBJETIVOS: El objetivo general es validar una nueva herramienta de evaluación de los flexores cervicales profundos. Para ello, se busca determinar una presión óptima del Stabilizer con el test y obtener valores de referencia del mismo. Además, se pretende analizar todas las variables posibles: diferencias por género y entre las superficies de evaluación. MATERIAL Y MÉTODOS: Diseño observacional descriptivo transversal, con una muestra de edad entre 18 y 65 años de población estudiantil de la Universidad Miguel Hernández. Se diseñan dos sesiones que incluyen una prueba de fatigabilidad y de variabilidad con Stabilizer, dispositivo de medición para evaluar y proporcionar retroalimentación, y finalmente una sesión para obtener valores de normalidad en población sana. RESULTADOS: Se espera encontrar diferencias significativas entre la evaluación en camilla y esterilla, así como entre géneros en la resistencia de la musculatura evaluada. Se espera establecer una presión óptima y obtener valores de referencia del test con una correlación con el Índice de Discapacidad Cervical. Este estudio pretende proporcionar una base sólida para futuras investigaciones y aplicaciones clínicas en el abordaje del dolor cervical en fisioterapia.es_ES
dc.description.abstractINTRODUCTION: Cervical pain is an increasing global health issue, with a prevalence of 20% and a persistence rate of up to 50% after one year. The weakness of the deep cervical flexors has been identified as a relevant factor in the etiology of this pain, making their assessment essential for an adequate clinical approach. AIMS: The general aim is to validate a new tool for assessing the endurance of the deep cervical flexors. This involves determining an optimal pressure for the Stabilizer test and obtaining reference values for it. Additionally, the study aims to explore potential differences between genders and between assessment surfaces to analyze all possible variables. MATERIAL AND METHODS: A cross-sectional descriptive observational design is employed. A sample of individuals aged between 18 and 65 years from the student population of Miguel Hernández University is estimated. Two sessions are designed, including a test for fatigue and variability of the Stabilizer, a measuring device that uses a manometer to evaluate and provide feedback on the pressure exerted, and finally a session to obtain normal values in a healthy population. RESULTS: Significant differences are anticipated between evaluations on a treatment table and mat, as well as gender differences. The study expects to establish an optimal pressure and obtain reference values for the test with a correlation to the Cervical Disability Index. This study will provide a solid foundation for future research and clinical applications.es_ES
dc.formatapplication/pdfes_ES
dc.format.extent49es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Miguel Hernándezes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectCervicalgiaes_ES
dc.subjectStabilizeres_ES
dc.subjectTest de Resistencia de los Flexores Profundos Cervicaleses_ES
dc.subjectFisioterapiaes_ES
dc.subject.otherCDU::6 - Ciencias aplicadases_ES
dc.titleEstandarización del test de resistencia de los flexores profundos cervicales con el Stabilizer: Diseño de estudio observacionales_ES
dc.typeinfo:eu-repo/semantics/bachelorThesises_ES
Aparece en las colecciones:
TFG - Fisioterapia


Vista previa

Ver/Abrir:
 TFG CHAER RIAN, RANIA .docx.pdf

1,98 MB
Adobe PDF
Compartir:


Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.