Please use this identifier to cite or link to this item: https://hdl.handle.net/11000/32415
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCaballero, Claudia-
dc.contributor.authorRodriguez, Fernando-
dc.contributor.authorCastro Cortellari, Guillermo-
dc.contributor.authorScarano, Antonio-
dc.contributor.authorPrados-Frutos, Juan Carlos-
dc.contributor.authorDe Aza, Piedad N.-
dc.contributor.authorOliveira Fernandes, Gustavo Vicentis-
dc.contributor.authorGehrke, Sergio Alexandre-
dc.contributor.otherDepartamentos de la UMH::Ciencia de Materiales, Óptica y Tecnología Electrónicaes_ES
dc.date.accessioned2024-07-03T07:15:15Z-
dc.date.available2024-07-03T07:15:15Z-
dc.date.created2024-
dc.identifier.citationJournal of Functional Biomaterials, 2024, 15, 177.es_ES
dc.identifier.issn2079-4983-
dc.identifier.urihttps://hdl.handle.net/11000/32415-
dc.description.abstractThe present study evaluated the mechanical behavior of five designs of Morse taper (MT) connections with and without the application of loads. For this, the detorque of the fixing screw and the traction force required to disconnect the abutment from the implant were assessed. A total of 100 sets of implants/abutments (IAs) with MT-type connections were used, comprising five groups (n = 20/group): (1) Group Imp 11.5: IA sets with a cone angulation of 11.5◦ ; (2) Group SIN 11.5: with a cone angulation of 11.5◦ ; (3) Group SIN 16: with a cone angulation of 16◦ ; (4) Group Neo 16: with a cone angulation of 16◦ ; and (5) Group Str 15: with a cone angulation of 15◦ . All sets received the torque recommended by the manufacturer. After applying the torque, the counter torque of the fixing screws was measured in ten IA sets of each group without the application of cyclic loads (frequencies ≤ 2 Hz, 360,000 cycles, and force at 150 Ncm). The other ten sets of each group were subjected to cyclic loads, after which the detorque was measured. Afterwards, the force for disconnection between the implant and the abutment was measured by traction on all the samples. The untwisting of the abutment fixation screws showed a decrease in relation to the initial torque applied in all groups. In the unloaded samples, it was found to be −25.7% in Group 1, −30.4% in Group 2, −36.8% in Group 3, −29.6% in Group 4, and −25.7% in Group 5. After the applied loads, it was found to be −44% in Group 1, −43.5% in Group 2, −48.5% in Group 3, −47.2% in Group 4, and −49.8% in Group 5. The values for the IA sets were zero for SIN 16 (Group 3) and Neo16 (Group 4), both without and with loads. In the other three groups, without loads, the disconnection value was 56.3 ± 2.21 N (Group 1), 30.7 ± 2.00 N (Group 2), and 26.0 ± 2.52 N (Group 5). After applying loads, the values were 63.5 ± 3.06 N for Group 1, 34.2 ± 2.45 N in Group 2, and 23.1 ± 1.29 N in Group 5. It was concluded that in terms of the mechanical behavior of the five designs of MT IA sets, with and without the application of loads, the Imp 11.5, SIN 11.5, and Srt 15 groups showed better results compared to the SIN 16 and Neo 16 groups, showing that lower values of cone angulation increase the friction between the parts (IA), thus avoiding the need to maintain the torque of the fixing screw to maintain the union of the sets.es_ES
dc.formatapplication/pdfes_ES
dc.format.extent11es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectabutment screw detorquees_ES
dc.subjectcone anglees_ES
dc.subjectdisconnection forcees_ES
dc.subjectmechanical loades_ES
dc.subjectMorse taper connectionses_ES
dc.subject.otherCDU::6 - Ciencias aplicadas::62 - Ingeniería. Tecnologíaes_ES
dc.titleMechanical Behavior of Five Different Morse Taper Implants and Abutments with Different Conical Internal Connections and Angles: An In Vitro Experimental Studyes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.relation.publisherversionhttps://doi.org/10.3390/jfb15070177es_ES
Appears in Collections:
Artículos CIENCIA DE LOS MATERIALES ÓPTICA Y TECNOLOGÍA ELECTRÓNICA


Thumbnail

View/Open:
 2024-jfb-15-00177 SergioG.pdf

2,06 MB
Adobe PDF
Share:


Creative Commons ???jsp.display-item.text9???