Por favor, use este identificador para citar o enlazar este ítem:
https://hdl.handle.net/11000/31037
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Galarza, Marcelo | - |
dc.contributor.author | Giménez, Ángel | - |
dc.contributor.author | AMIGO, JOSE M. | - |
dc.contributor.author | Schuhmann, Martin | - |
dc.contributor.author | Gazzeri, Roberto | - |
dc.contributor.author | Thomale, Ulrich-Wilhelm | - |
dc.contributor.author | McAllister, James P. | - |
dc.contributor.other | Departamentos de la UMH::Estadística, Matemáticas e Informática | es_ES |
dc.date.accessioned | 2024-02-05T11:21:35Z | - |
dc.date.available | 2024-02-05T11:21:35Z | - |
dc.date.created | 2017 | - |
dc.identifier.citation | Child's Nervous System (2018) 34 | es_ES |
dc.identifier.issn | 1433-0350 | - |
dc.identifier.issn | 0256-7040 | - |
dc.identifier.uri | https://hdl.handle.net/11000/31037 | - |
dc.description.abstract | Background The flow pattern of the cerebrospinal fluid is probably the most important factor related to obstruction of ventricular catheters during the normal treatment of hydro cephalus. To better comprehend the flow pattern, we have carried out a parametric study via numerical models of ven tricular catheters. In previous studies, the flow was studied under steady and, recently, in pulsatile boundary conditions by means of computational fluid dynamics (CFD) in three dimensional catheter models. Objective This study aimed to bring in prototype models of catheter CFD flow solutions as well to introduce the theory behind parametric development of ventricular catheters. Methods A preceding study allowed deriving basic principles which lead to designs with improved flow patterns of ventric ular catheters. The parameters chosen were the number of drainage segments, the distances between them, the number and diameter of the holes on each segment, as well as their relative angular position. Results CFD results of previously unreleased models of ven tricular catheter flow solutions are presented in this study. Parametric development guided new designs with better flow distribution while lowering the shear stress of the catheters holes. High-resolution 3D printed catheter solutions of three models and basic benchmark testing are introduced as well. Conclusions The next generation of catheter with homoge neous flow patterns based on parametric designs may repre sent a step forward for the treatment of hydrocephalus, by possibly broadening their lifespan. | es_ES |
dc.format | application/pdf | es_ES |
dc.format.extent | 10 | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Springer | es_ES |
dc.rights | info:eu-repo/semantics/closedAccess | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Catheter obstruction | es_ES |
dc.subject | Shunt revision | es_ES |
dc.subject | Flow | es_ES |
dc.subject | Cerebrospinal fluid | es_ES |
dc.subject | Cerebral ventricle | es_ES |
dc.subject | Catheter prototypes | es_ES |
dc.subject.other | CDU::5 - Ciencias puras y naturales | es_ES |
dc.title | Next generation of ventricular catheters for hydrocephalus based on parametric design | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.relation.publisherversion | https://doi.org/10.1007/s00381-017-3565-0 | es_ES |
Ver/Abrir:
7-2018-NextGenerationVentricularCathetersHydrocephalusBasedParametricDesigns.pdf
6,61 MB
Adobe PDF
Compartir:
La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.