Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/28979

Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles


Vista previa

Ver/Abrir:
 Scientific Repors Sergio.pdf

3,25 MB
Adobe PDF
Compartir:
Título :
Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles
Autor :
Gehrke, Sergio  
Aramburú Junior, Jaime  
EirlesTreichel, Tiago Luis
Dias do Prado, Tales
Anina Dedavid, Berenice
De Aza, Piedad  
Editor :
Universidad Miguel Hernández de Elche
Departamento:
Departamentos de la UMH::Ciencia de Materiales, Óptica y Tecnología Electrónica
Fecha de publicación:
2022-01
URI :
https://hdl.handle.net/11000/28979
Resumen :
The aim of the present in vivo study was to analyze and compare the effects on the crestal bone healing of two different implant macrogeometries installed in fresh socket areas and in normal bone areas with different insertion torque values. Two implant macrogeometries were used in the present study, DuoCone implant (DC) and Maestro implant (MAE), forming four groups: group DCws, in which the implants were installed in healing bone (without a socket); group DCfs, in which the implants were installed in post-extraction areas (fresh sockets); group MAEws, in which the implants were installed in healing bone (without a socket); group MAEfs, in which the implants were installed in post-extraction areas (fresh sockets). After 30 and 90 days of implantations in the bilateral mandibles of 10 sheep, eighty implants were evaluated through digital X-ray images and histologic slices. The crestal bone position in relation to the implant platform shoulder was measured and compared. The measured insertion torque was 47.2 ± 4.69 Ncm for the DCws group, 43.4 ± 4.87 Ncm for the DCfs group, 29.3 ± 3.16 Ncm for the MAEws group, and 27.7 ± 4.41 Ncm for the MAEfs group. The radiographic mesio-distal and histological bucco-lingual analyses showed significantly greater vertical bone loss in the implants installed with high torque (DC groups) in comparison to the implants installed with a low torque (MAE groups) (p < 0.05), at both evaluation times. In general, low insertion torque values (Maestro implants) showed better results of MBL when compared to implants installed with higher torque values (Duo Cone implants). Moreover, our results showed that the implants installed in the sites without sockets showed a less MBL in comparison with the implants installed in sites of fresh sockets.
Área de conocimiento :
CDU: Ciencias aplicadas: Ingeniería. Tecnología: Ensayo de materiales. Materiales comerciales. Economía de la energía
Tipo de documento :
info:eu-repo/semantics/article
Derechos de acceso:
info:eu-repo/semantics/openAccess
Aparece en las colecciones:
Artículos CIENCIA DE LOS MATERIALES ÓPTICA Y TECNOLOGÍA ELECTRÓNICA



Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.