Please use this identifier to cite or link to this item: https://hdl.handle.net/11000/25978
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorMoreno Pérez, Víctor-
dc.contributor.advisorMiralles Iborra, Aarón-
dc.contributor.authorColado Sánchez, Juan José-
dc.contributor.otherDepartamentos de la UMH::Ciencias del Deportees_ES
dc.date.accessioned2022-02-24T11:53:41Z-
dc.date.available2022-02-24T11:53:41Z-
dc.date.created2021-06-25-
dc.identifier.urihttp://hdl.handle.net/11000/25978-
dc.description.abstractEl objetivo de este trabajo es investigar la fiabilidad intrasesion e intersesión de un sistema innovador que permite determinar la contracción voluntaria máxima y la RFD de cuádriceps e isquiosurales en un ángulo de 30º de flexión de rodilla con el fin de obtener un instrumento menos costoso y fiable para su uso tanto en fútbol amateur como profesional. Veintiún futbolistas juveniles masculinos participaron en el test-retest durante 2 sesiones (una de ellas con una parte de familiarización) separadas por 1 semana de diferencia. La contracción voluntaria máxima se midió durante 4-5 segundos y la RFD durante los primeros milisegundos de la contracción. El análisis estadístico se realizó con una hoja de cálculo específica por pares utilizando el índice de correlación intraclase (ICC), el error estándar de medida en valores absolutos (SEM) y como coeficiente de variación (%SEM) y el mínimo cambio detectable (MDC).es_ES
dc.description.abstractThe aim of this project is to investigate the intrassesion and interssesion reliability of an innovative system that allows determining the maximum voluntary contraction (MVC) and RFD of quadriceps and hamstring at a 30º knee flexion angle to obtain a less expensive and reliable instrument for use in both amateur and professional football. Twenty-one male youth football players participated in the test-retest during 2 sessions (one of them with a familiarization part) separated by 1 week apart. The maximum voluntary contraction was measured during 4-5 second and the RFD during the first milliseconds of the contraction. Statistical analysis was performed with a specific spreadsheet for consecutive pairs using the intraclass correlation index (ICC), the standard error of measurement in absolute values (SEM) and as coefficient of variation (%SEM) and the minimum detectable change (MDC).es_ES
dc.formatapplication/pdfes_ES
dc.format.extent14es_ES
dc.language.isospaes_ES
dc.publisherUniversidad Miguel Hernández de Elchees_ES
dc.relation.ispartofCentro de Investigación del Deportees_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectContracción voluntaria máximaes_ES
dc.subjectRatio de desarrollo de la Fuerzaes_ES
dc.subjectCuádricepses_ES
dc.subjectIsquiosuraleses_ES
dc.subjectFútboles_ES
dc.subject.otherCDU:79 -Deporteses_ES
dc.titleFiabilidad inter-e intrasesión de un sistema innovador que permite medir la contracción voluntaria máxima y la ratio de desarrollo de la fuerza de cuádriceps e isquiosuraleses_ES
dc.typeinfo:eu-repo/semantics/masterThesises_ES
Appears in Collections:
TFM - M.U en Rendimiento Deportivo y Salud


Thumbnail

View/Open:
 Colado Sánchez, Juan José_TFM.pdf

436,68 kB
Adobe PDF
Share:


Creative Commons ???jsp.display-item.text9???