Publication: Transient modeling of high-inertial thermal bridges in buildings using the equivalent thermal wall method
Loading...
Author
Journal Title
Journal ISSN
Volume Title
Date
Citation
Applied Thermal Engineering, vol. 67 (2014)
Conference
Publisher
Abstract
The method of the equivalent thermal wall has been employed for modeling the transient response of
high-inertial thermal bridges. A new strategy is presented in order to adjust the thermal properties of the
equivalent three-layered wall, which takes into account the temperature distribution across the thermal
bridge in a steady-state heat conduction scenario. Two different thermal bridge topologies created by the
junction of a vertical wall and an intermediate or a ground floor slab are analyzed with this method, and
its feasibility for the implementation in building energy simulation tools is discussed: if the thermal
bridge is not considered, an underestimation of 25% in the heat flux across the bridge is predicted. If the
thermal bridge is modeled but its thermal inertia is neglected, a time-delayed heat flux response is
retrieved. Conversely, the simulation based on the equivalent wall method provides a response nearly
identical to the actual dynamic performance of the thermal bridge.