Publication: Effect of Vacuum Level and Pulsation Parameters on Milking Efficiency and Animal Welfare of Murciano Granadina Goats Milked in Mid-Line and Low-Line Milking Machines
Loading...
Author
Martínez, Manuel Alejandro
Bueso Ródenas, Joel
Moya, Francisco
Journal Title
Journal ISSN
Volume Title
Date
Citation
Animals 2022, 12(1), 40
Conference
Publisher
MDPI
Abstract
The Murciano-Granadina goat breed has been described as a slow milking breed. As
milking machine parameters can affect milk extraction in terms of yield and time employed, two experiments of one-month duration were performed with 88 goats in Latin square design to find the best
combination of these parameters. One of them was carried out in a mid-line milking machine and one
in a low-line milking machine. For each of them, two vacuum levels (36 and 40 kPa), two pulsation
rates (90 and 120 cycles/min) and two pulsator ratios (50 and 60%) were used and milking efficiency,
sanitary status of the mammary gland, milk cortisol, and teat end status were evaluated. Results
showed that in milking machines installed in mid- and low-line, the use of 40 kPa system vacuum,
60% pulsator ratio and 90 or 120 cycles/min pulsation rate achieved optimum milking fractioning
and efficiency. In the case of low-level milking machines, a similar combination with 36 kPa not only
showed worse milking fractioning values, but also provided better values of teat end status and
cortisol level.