Publication:
Effect of Vacuum Level and Pulsation Parameters on Milking Efficiency and Animal Welfare of Murciano Granadina Goats Milked in Mid-Line and Low-Line Milking Machines

Loading...
Thumbnail Image

Author

Martínez, Manuel Alejandro
Bueso Ródenas, Joel
Moya, Francisco

Journal Title

Journal ISSN

Volume Title

Date

Citation

Animals 2022, 12(1), 40

Conference

Publisher

MDPI

Abstract

The Murciano-Granadina goat breed has been described as a slow milking breed. As milking machine parameters can affect milk extraction in terms of yield and time employed, two experiments of one-month duration were performed with 88 goats in Latin square design to find the best combination of these parameters. One of them was carried out in a mid-line milking machine and one in a low-line milking machine. For each of them, two vacuum levels (36 and 40 kPa), two pulsation rates (90 and 120 cycles/min) and two pulsator ratios (50 and 60%) were used and milking efficiency, sanitary status of the mammary gland, milk cortisol, and teat end status were evaluated. Results showed that in milking machines installed in mid- and low-line, the use of 40 kPa system vacuum, 60% pulsator ratio and 90 or 120 cycles/min pulsation rate achieved optimum milking fractioning and efficiency. In the case of low-level milking machines, a similar combination with 36 kPa not only showed worse milking fractioning values, but also provided better values of teat end status and cortisol level.

Journal Title

DOI

Center

ISBN

Subjects

Advisor

Alternative title

Funder