Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/37867

A novel device for temporary cardiac stimulation using permanent pacemaker generators and active-fixation leads: the TEMPACE multicentre prospective study


Vista previa

Ver/Abrir:
 A novel device for temporary cardiac.pdf

2,92 MB
Adobe PDF
Compartir:
Título :
A novel device for temporary cardiac stimulation using permanent pacemaker generators and active-fixation leads: the TEMPACE multicentre prospective study
Autor :
Vicente-Miralles, Raimundo  
Rivas-Gándara, Nuria  
Jordán Marchite, Pablo
Adeliño, Raquel  
Carmona, María Ángeles
Díaz Barranco, Mónica
Ibañez Criado, Alicia Ascensión
Ruiz Nodar, Juan Miguel
Ajo Ferrer, María  
García-Fernández, Amaya  
Bertomeu-González, Vicente  
Martínez Martínez, Juan Gabriel
Editor :
European Society of Cardiology
Departamento:
Departamentos de la UMH::Medicina Clínica
Fecha de publicación:
2025-08
URI :
https://hdl.handle.net/11000/37867
Resumen :
To determine the safety and effectiveness of the KronoSafe® permanent pacemaker adapter for temporary cardiac pacing (TCP) with active-fixation leads (TCPAFL). Methods: This was a multicenter, prospective, descriptive clinical investigation involving a medical device (ClinicalTrials.gov Identifier: NCT05351658). Between January 2023 and December 2024, all consecutive patients who underwent implantation of a temporary active-fixation pacemaker were included. The devices were secured using the KronoSafe® adapter throughout the period of use. Complications during TCPAFL were recorded, and R-wave sensing, lead impedance, and pacing threshold were determined every 48 hours. Results: Thirty patients (10 with atrioventricular block, 9 TAVI, 5 alcohol septal ablations, 2 slow atrial fibrillations, 2 bradycardia-tachycardia syndrome, and 2 pacemaker infections) who required TCP were included. Two centers participated in the study. The mean duration of TCP was 7.8 days (maximum 22 days), with 79.2% of the time spent in the cardiology ward. One complication (3%) was recorded, due to accidental traction of the system associated with an episode of agitation. Conclusions: TCPAFL using the KronoSafe® adapter is safe and effective, and its use can be extended outside the Intensive Care Unit.
Palabras clave/Materias:
external permanent pacemaker
temporary pacemaker
temporaryt pacemaker with active-fixation leads
temporary-permanent pacemaker
Tipo de documento :
info:eu-repo/semantics/article
Derechos de acceso:
info:eu-repo/semantics/openAccess
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
DOI :
10.1093/ehjacc/zuaf111
Publicado en:
Eur Heart J Acute Cardiovasc Care . 2025 Aug 28:zuaf111
Aparece en las colecciones:
Artículos Medicina Clínica



Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.