Por favor, use este identificador para citar o enlazar este ítem: https://hdl.handle.net/11000/34490

MiSight Assessment Study Spain: Adverse Events, Tear Film Osmolarity, and Discontinuations


no-thumbnailVer/Abrir:

 3_Misight adverse.pdf



8,3 MB
Adobe PDF
Compartir:

Este recurso está restringido

Título :
MiSight Assessment Study Spain: Adverse Events, Tear Film Osmolarity, and Discontinuations
Autor :
Pérez-Sánchez, Belén  
Ruiz Pomeda, Alicia  
Prieto Garrido, francisco luis  
Gutiérrez Ortega, Angel Ramón  
Villa-Collar, Cesar  
Editor :
Lippincott, Williams & Wilkins
Departamento:
Departamentos de la UMH::Estadística, Matemáticas e Informática
Fecha de publicación:
2018
URI :
https://hdl.handle.net/11000/34490
Resumen :
Abstract Objectives: To assess the relative clinical success of MiSight contact lenses (CLs) (study group) and distance single-vision (SV) spectacles (control group) in children in terms of adverse events (AEs), discontinuations, and tear film osmolarity over a 2-year period. Methods: Seventy-four subjects aged 8 to 12 with myopia of −0.75 to −4.00 D and astigmatism less than 1.00 D were randomly assigned to MiSight CLs or SV groups. Subjects were monitored at 6-month intervals over the course of 24 months and advised to report to the clinic immediately should AEs occur. Adverse events were categorized as serious, significant, and nonsignificant. Discontinuation was defined as cessation of participation in the study. Results: Forty-four children were corrected with MiSight CLs and 33 with SV spectacles. No serious or significant AEs were found in any of the participants in either group. Two nonsignificant AEs were found in MiSight group, corresponding to a foreign body on the cornea in two children. There were five discontinuations in MiSight group, one because of change of residence and four because of unwillingness to use the CL. There were no discontinuations in SV group. Neither group showed any significant changes in osmolarity data over the 24 months of follow-up (P≥0.05). Conclusions: No clinically serious events were observed in either group. Our results show that correct use of MiSight CLs is a safe option for myopia correction. The success of this treatment requires a combination of proper lens fitting, good adherence to routine follow-ups, and timely treatment of complications.
Palabras clave/Materias:
MiSight contact lens
Adeverse events
Discontinuation
Osmolarity
Área de conocimiento :
CDU: Ciencias puras y naturales: Matemáticas
Tipo de documento :
info:eu-repo/semantics/article
Derechos de acceso:
info:eu-repo/semantics/closedAccess
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
DOI :
https://doi.org/10.1097/ICL.0000000000000484
Aparece en las colecciones:
Artículos Estadística, Matemáticas e Informática



Creative Commons La licencia se describe como: Atribución-NonComercial-NoDerivada 4.0 Internacional.